Commit da195138 authored by PX4BuildBot's avatar PX4BuildBot

Update PX4 Firmware metadata Mon Apr 6 14:08:38 UTC 2020

parent 793d8d96
...@@ -422,12 +422,12 @@ Set to 2 to use heading from motion capture</short_desc> ...@@ -422,12 +422,12 @@ Set to 2 to use heading from motion capture</short_desc>
</parameter> </parameter>
<parameter default="0" name="BAT1_SOURCE" type="INT32"> <parameter default="0" name="BAT1_SOURCE" type="INT32">
<short_desc>Battery 1 monitoring source</short_desc> <short_desc>Battery 1 monitoring source</short_desc>
<long_desc>This parameter controls the source of battery data. The value 'Power Module' means that measurements are expected to come from a power module. If the value is set to 'External' then the system expects to receive mavlink battery status messages.</long_desc> <long_desc>This parameter controls the source of battery data. The value 'Power Module' means that measurements are expected to come from a power module. If the value is set to 'External' then the system expects to receive mavlink battery status messages. If the value is set to 'ESCs', the battery information are taken from the esc_status message. This requires the ESC to provide both voltage as well as current.</long_desc>
<unit>mAh</unit>
<reboot_required>True</reboot_required> <reboot_required>True</reboot_required>
<values> <values>
<value code="0">Power Module</value> <value code="0">Power Module</value>
<value code="1">External</value> <value code="1">External</value>
<value code="2">ESCs</value>
</values> </values>
</parameter> </parameter>
<parameter default="-1" name="BAT1_V_CHANNEL" type="INT32"> <parameter default="-1" name="BAT1_V_CHANNEL" type="INT32">
...@@ -522,12 +522,12 @@ Set to 2 to use heading from motion capture</short_desc> ...@@ -522,12 +522,12 @@ Set to 2 to use heading from motion capture</short_desc>
</parameter> </parameter>
<parameter default="0" name="BAT2_SOURCE" type="INT32"> <parameter default="0" name="BAT2_SOURCE" type="INT32">
<short_desc>Battery 2 monitoring source</short_desc> <short_desc>Battery 2 monitoring source</short_desc>
<long_desc>This parameter controls the source of battery data. The value 'Power Module' means that measurements are expected to come from a power module. If the value is set to 'External' then the system expects to receive mavlink battery status messages.</long_desc> <long_desc>This parameter controls the source of battery data. The value 'Power Module' means that measurements are expected to come from a power module. If the value is set to 'External' then the system expects to receive mavlink battery status messages. If the value is set to 'ESCs', the battery information are taken from the esc_status message. This requires the ESC to provide both voltage as well as current.</long_desc>
<unit>mAh</unit>
<reboot_required>True</reboot_required> <reboot_required>True</reboot_required>
<values> <values>
<value code="0">Power Module</value> <value code="0">Power Module</value>
<value code="1">External</value> <value code="1">External</value>
<value code="2">ESCs</value>
</values> </values>
</parameter> </parameter>
<parameter default="-1" name="BAT2_V_CHANNEL" type="INT32"> <parameter default="-1" name="BAT2_V_CHANNEL" type="INT32">
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment